Weighted least-squares in calibration: What difference does it make?

Literature Information

Publication Date 2007-04-18
DOI 10.1039/B701696D
Impact Factor 4.616
Authors

Joel Tellinghuisen


View Original

Abstract

In univariate calibration, an unknown concentration or amount x0 is estimated from its measured response y0 by comparison with a calibration data set obtained in the same way for known x values. The calibration function y = f(x) contains parameters obtained from a least-squares (LS) fit of the calibration data. Since minimum-variance estimation requires that the data be weighted inversely as their true variances, any other weighting leads to predictable losses of precision in the calibration parameters and in the estimation of x0. Incorrect weighting also invalidates the apparent standard errors returned by the LS calibration fit. Both effects are studied using Monte Carlo calculations. For the strongest commonly encountered heteroscedasticity, proportional error (σi ∝ yi), neglect of weights yields as much as an order of magnitude precision loss for x0 in the small x region, but only nominal loss in the calibration mid-range. Use of replicates gives great improvement at small x but can underperform unweighted regression in the mid-to-large x region. Variance function estimation approximates minimum-variance, even though the true variance functions are not well reproduced. A relative error test applied to the calibration data themselves is predisposed to favor 1/y2 (or 1/x2) weighting, even if the data are homoscedastic. This predisposition weakens when replicate measurements are taken and disappears when the test is applied to an independent set of data. The distinction between a priori and a posteriori parameter standard errors is emphasized. Where feasible, the a priori approach permits reliable assignment of weights, application of a χ2 test, and use of the normal distribution for confidence limits.

Related Literature

A fluorescent receptor for halide recognition: clues for the design of anion chemosensors

Andrea Bencini, Claudia Giorgi, Vito Lippolis, Pier Remigio Salvi

2015-03-16 Paper

DOI: 10.1039/C5CP00131E

Electrolyte ion adsorption and charge blocking effect at the hematite/aqueous solution interface: an electrochemical impedance study using multivariate data analysis

K. Shimizu, J. Nyström, P. Geladi, B. Lindholm-Sethson, J.-F. Boily

2015-03-31 Paper

DOI: 10.1039/C4CP05927A

In situ strain evolution during a disconnection event in a battery nanoparticle

Andrew Ulvestad, Andrej Singer, David Vine, H. M. Cho, Ross Harder, Ying Shirley Meng, Oleg G. Shpyrko

2015-03-16 Paper

DOI: 10.1039/C5CP00372E

Simultaneous DNP enhancements of 1H and 13C nuclei: theory and experiments

Daphna Shimon, Yonatan Hovav, Ilia Kaminker, Akiva Feintuch, Daniella Goldfarb, Shimon Vega

2015-04-14 Paper

DOI: 10.1039/C5CP00406C

Slow-to-fast transition of hydrogen bond dynamics in acetamide hydration shell formation

Francesco D'Amico, Gaia Camisasca, Filippo Bencivenga, Alessandro Gessini, Emiliano Principi, Riccardo Cucini, Claudio Masciovecchio

2015-03-23 Paper

DOI: 10.1039/C5CP00486A

Outside rules inside: the role of electron-active substituents in thiophene-based heterophenoquinones

L. Brambilla, E. Parisini, C. Castiglioni

2015-02-16 Paper

DOI: 10.1039/C4CP05748A

Order and disorder around Cr3+ in chromium doped persistent luminescent AB2O4 spinels

Neelima Basavaraju, Kaustubh R. Priolkar, Didier Gourier, Aurélie Bessière, Bruno Viana

2015-03-24 Paper

DOI: 10.1039/C5CP01097G

Enhancement of the thermoelectric figure of merit in DNA-like systems induced by Fano and Dicke effects

Hua-Hua Fu, Lei Gu, Dan-Dan Wu, Zu-Quan Zhang

2015-03-25 Paper

DOI: 10.1039/C4CP04382K

3-Methylpiperidinium ionic liquids

Tayeb Belhocine, Stewart A. Forsyth, H. Q. Nimal Gunaratne, Mark Nieuwenhuyzen, Peter Nockemann, Alberto V. Puga, Kenneth R. Seddon, Geetha Srinivasan, Keith Whiston

2015-01-28 Paper

DOI: 10.1039/C4CP05936K

You might also like

Compound Q&A

Is 2-(2-chloroacetamido)-3-phenylpropanoic acid (CAS: 7765-11-9) safe?

2-(2-Chloroacetamido)-3-phenylpropanoic acid (CAS: 7765-11-9) is generally consi...

7765-11-92-(2-chloroacetamido...
Compound Q&A

Is 2-(Benzyloxy)-5-bromobenzoic acid (CAS: 62176-31-2) safe?

2-(Benzyloxy)-5-bromobenzoic acid can be handled safely if appropriate precautio...

62176-31-22-(Benzyloxy)-5-brom...
Compound Q&A

What is (4-Methyl-1,2,5-oxadiazol-3-yl)methanamine hydrochloride (CAS: 1159825-48-5)?

(4-Methyl-1,2,5-oxadiazol-3-yl)methanamine hydrochloride is a chemical compound ...

1159825-48-5(4-Methyl-1,2,5-oxad...
Compound Q&A

What is 2-(5-Hexylthiophen-2-yl)-4,4,5,5-tetramethyl-1,3,2-dioxaborolane (CAS: 917985-54-7)?

2-(5-Hexylthiophen-2-yl)-4,4,5,5-tetramethyl-1,3,2-dioxaborolane (CAS: 917985-54...

917985-54-72-(5-Hexylthiophen-2...
Compound Q&A

Are there alternatives to 4-(8-Methyl-9H-1,3-dioxolo[4,5-h][2,3]benzodiazepin-5-yl)benzenamine (CAS: 102771-26-6) in synthesis?

While 4-(8-Methyl-9H-1,3-dioxolo[4,5-h][2,3]benzodiazepin-5-yl)benzenamine (CAS:...

102771-26-64-(8-Methyl-9H-1,3-d...
Compound Q&A

What is the market or research trend for tert-butyl 3-hydroxy-4,5,7,8-tetrahydro-2H-pyrazolo[3,4-d]azepine-6-carboxylate (CAS: 851376-80-2)?

The market for tert-butyl 3-hydroxy-4,5,7,8-tetrahydro-2H-pyrazolo[3,4-d]azepine...

851376-80-2tert-butyl 3-hydroxy...
Compound Q&A

How should waste containing 3,5-Diamino-1H-pyrazole-4-carbonitrile (CAS: 6844-58-2) be handled?

Waste containing 3,5-Diamino-1H-pyrazole-4-carbonitrile (CAS: 6844-58-2) should ...

6844-58-23,5-Diamino-1H-pyraz...
Compound Q&A

How is (6-Fluoro-3-pyridinyl)boronic acid (CAS: 351019-18-6) typically synthesized?

(6-Fluoro-3-pyridinyl)boronic acid can be synthesized through the reaction of 6-...

351019-18-6(6-Fluoro-3-pyridiny...
Compound Q&A

What industries use Dibenzyl carbonimidoylbiscarbamate (CAS: 10065-79-9)?

Dibenzyl carbonimidoylbiscarbamate (CAS: 10065-79-9) finds applications in vario...

10065-79-9Dibenzyl carbonimido...
Compound Q&A

What is the market or research trend for (beta,beta,2,3,4,5,6-~2~H_7_)Phenylalanine (CAS: 74228-83-4)?

The market for (beta,beta,2,3,4,5,6-~2~H_7_)Phenylalanine (CAS: 74228-83-4) is g...

74228-83-4(beta,beta,2,3,4,5,6...

Source Journal

Analyst

Analyst
CiteScore: 7.8
Self-citation Rate: 5.6%
Articles per Year: 653

Analyst publishes analytical and bioanalytical research that reports premier fundamental discoveries and inventions, and the applications of those discoveries, unconfined by traditional discipline barriers.

Recommended Suppliers

Disclaimer
This page provides academic journal information for reference and research purposes only. We are not affiliated with any journal publishers and do not handle publication submissions. For publication-related inquiries, please contact the respective journal publishers directly.
If you notice any inaccuracies in the information displayed, please contact us at support@chemtradehub.com. We will promptly review and address your concerns.