Solid phase microextraction coupled to mass spectrometry via a microfluidic open interface for rapid therapeutic drug monitoring

Literature Information

Publication Date 2019-04-03
DOI 10.1039/C9AN00041K
Impact Factor 4.616
Authors

Nikita T. Looby, Tijana Vasiljevic, Marcin Wąsowicz, Janusz Pawliszyn


View Original

Abstract

Tranexamic acid (TXA) is an antifibrinolytic used during cardiac surgery that presents high inter-patient variability. High plasma concentrations have been associated with post-operative seizures. Due to the difficulties with maintaining acceptable concentrations of TXA during surgery, implementation of a point-of-care strategy for testing TXA plasma concentration would allow for close monitoring of its concentration during administration. This would facilitate timely corrections to the dosing schedule, and in effect tailor treatment for individual patient needs. In this work, a method for the rapid monitoring of TXA from plasma samples was subsequently carried out via biocompatible solid-phase microextraction (Bio-SPME) coupled directly to tandem mass spectrometry via a microfluidic open interface (MOI). MOI operates under the concept of a flow-isolated desorption volume and was designed with aims to directly hyphenate Bio-SPME to different detection and ionization systems. In addition, it allows the desorption of Bio-SPME fibers in small volumes while it concurrently continues feeding the ESI with a constant flow to minimize cross-talking and instabilities. The methodology was used to monitor six patients with varying degrees of renal dysfunction, at different time points during cardiac surgery. MOI proves to be a reliable and feasible tool for rapid therapeutic drug monitoring. Affording total times of analysis as low as 30 seconds per sample in its high throughput mode configuration while the single sample turn-around time was 15 minutes, including sample preparation. In addition, cross-validation against a standard thin film solid phase microextraction using liquid chromatography coupled to tandem mass spectrometry (TFME-LC-MS/MS) method was performed. Bland–Altman analysis was used to cross-validate the results obtained by the two methods. Data analysis demonstrated that 92% of the compared data pairs (n = 63) were distributed within the acceptable range. The data was also validated by the Passing Bablok regression, demonstrating good statistical agreement between these two methods. Finally, the currently presented method offers comparable results to the conventional liquid chromatography with acceptable RSDs, while only necessitating a fraction of the time. In this way, TXA concentration in plasma can be monitored in a close to real time throughput during surgery.

Related Literature

First-principles comparative study of perfect and defective CsPbX3 (X = Br, I) crystals

R. A. Evarestov, A. Senocrate, R. K. Kremer, J. Maier

2020-01-27 Paper

DOI: 10.1039/C9CP06322F

Structural relationships for the design of responsive azobenzene-based lyotropic liquid crystals

Luke W. Giles, Joshua B. Marlow, Calum S. G. Butler, Geosmin A. Turpin, Liliana de Campo, Stephen T. Mudie, Charl F. J. Faul, Rico F. Tabor

2020-01-30 Paper

DOI: 10.1039/C9CP05463D

A molecular device providing a remarkable spin filtering effect due to the central molecular stretch caused by lateral zigzag graphene nanoribbon electrodes

Xiaoyue Liu, Jueming Yang, Xingwu Zhai, Hongxia Yan, Yanwen Zhang, Long Zhou

2020-02-28 Paper

DOI: 10.1039/D0CP00238K

Photoemission from non-polar aromatic molecules in the gas and liquid phase

L. Longetti, M. Randulová, J. Ojeda, L. Mewes, L. Miseikis, J. Grilj, A. Sanchez-Gonzalez, T. Witting, T. Siegel, Z. Diveki, F. van Mourik, R. Chapman, C. Cacho, S. Yap, J. W. G. Tisch, E. Springate, J. P. Marangos, P. Slavíček, M. Chergui

2020-01-29 Paper

DOI: 10.1039/C9CP06799J

Inside front cover

Cover

DOI: 10.1039/D0CP90062A

You might also like

Compound Q&A

What is the market or research trend for N-(4-Methoxybenzyl)-2-pyridinamine (CAS: 52818-63-0)?

N-(4-Methoxybenzyl)-2-pyridinamine (CAS: 52818-63-0) is increasingly being used ...

52818-63-0N-(4-Methoxybenzyl)-...
Compound Q&A

What precautions should be taken when handling Ethyl 4-(2-chlorophenyl)-1,3-thiazole-2-carboxylate (CAS: 1050507-06-6)?

When handling Ethyl 4-(2-chlorophenyl)-1,3-thiazole-2-carboxylate, appropriate p...

1050507-06-6Ethyl 4-(2-chlorophe...
Compound Q&A

What regulatory guidelines apply to diethyldiselane (CAS: 628-39-7)?

Diethyldiselane (CAS: 628-39-7) is classified under the Globally Harmonized Syst...

628-39-7Diethyldiselane
Compound Q&A

What is the market or research trend for oxocopper (CAS: 12053-18-8)?

The market for oxocopper (CAS: 12053-18-8) is primarily driven by its use in cat...

12053-18-8oxocopper; oxo-(oxoc...
Compound Q&A

What is the market or research trend for 5-{[(2-Methyl-2-propanyl)oxy]carbonyl}-5-azaspiro[2.4]heptane-7-carboxylic acid?

The market for 5-{[(2-Methyl-2-propanyl)oxy]carbonyl}-5-azaspiro[2.4]heptane-7-c...

1268519-54-55-{[(2-Methyl-2-prop...
Compound Q&A

What is 2-(1-Pyrrolidinyl)-4-pyridinamine (CAS: 35981-63-6)?

2-(1-Pyrrolidinyl)-4-pyridinamine is a chemical compound with the CAS number 359...

35981-63-62-(1-Pyrrolidinyl)-4...
Compound Q&A

What are the physical and chemical properties of 2-(3-Pyridinyl)-1-azabicyclo[2.2.2]octane (CAS: 91556-75-1)?

2-(3-Pyridinyl)-1-azabicyclo[2.2.2]octane (CAS: 91556-75-1) is a crystalline sol...

91556-75-12-(3-Pyridinyl)-1-az...
Compound Q&A

How is (S)-Alpha-allyl-proline hydrochloride (CAS: 129704-91-2) typically synthesized?

(S)-Alpha-allyl-proline hydrochloride is usually synthesized via a Wittig reacti...

129704-91-2(S)-Alpha-allyl-prol...
Compound Q&A

What is 3-Methyl-1,2-oxazole-5-carboxylic acid (CAS: 4857-42-5)?

3-Methyl-1,2-oxazole-5-carboxylic acid (CAS: 4857-42-5) is an organic compound w...

4857-42-53-Methyl-1,2-oxazole...
Compound Q&A

How is Lys-SMCC-DM1 (CAS: 1281816-04-3) typically synthesized?

Lys-SMCC-DM1 is synthesized via a multi-step process involving the coupling of S...

1281816-04-3Lys-SMCC-DM1

Source Journal

Analyst

Analyst
CiteScore: 7.8
Self-citation Rate: 5.6%
Articles per Year: 653

Analyst publishes analytical and bioanalytical research that reports premier fundamental discoveries and inventions, and the applications of those discoveries, unconfined by traditional discipline barriers.

Recommended Compounds

Recommended Suppliers

Disclaimer
This page provides academic journal information for reference and research purposes only. We are not affiliated with any journal publishers and do not handle publication submissions. For publication-related inquiries, please contact the respective journal publishers directly.
If you notice any inaccuracies in the information displayed, please contact us at support@chemtradehub.com. We will promptly review and address your concerns.