Precise determination of lead isotope ratios by MC-ICP-MS without matrix separation exemplified by unique samples of diverse origin and history

Literature Information

Publication Date 2023-10-04
DOI 10.1039/D3JA00259D
Impact Factor 4.023
Authors

Jakub Karasiński, Ewa Bulska, Andrii Tupys, Barbara Wagner


View Original

Abstract

This study evaluates the feasibility of using the internal standard (IS) method and optimized regression model (ORM) to determine lead isotope ratios without separating Pb from many different types of matrices. The effect of typical interferents at increasing concentrations was investigated using model samples. We have demonstrated that Pb isotope ratio measurements without matrix separation give equally accurate and precise results as those obtained with matrix separation. Finally we used a new protocol to measure the isotope ratio of Pb in environmental, geological and archaeological samples with very limited availability (3 mg) and low lead content (30 mg kg−1). Such samples have so far been problematic for MC-ICP-MS isotopic analysis due to the difficulties with separating such small amounts of lead using ion exchange resins. Lead isotope ratios were measured without separation of lead from the sample using two protocols. In the first, the internal standard method was used as a means of calibration. In the second, the optimized regression model was used. In this case there were no statistically significant differences between the protocols compared. Both approaches gave statistically similar results. The protocol using IS is recommended as it is significantly simpler and less laborious and consumes lower volumes of sample solution. The protocol we developed can be applied to a wide range of samples (following some recommendations). To demonstrate the usefulness of the new procedure, we applied it to different types of samples containing lead at different concentrations. In particular, we focused on historical samples because their availability is very limited and collecting a sufficiently large sample is always a major problem. Where possible, we compared our results with literature values. The new protocol, by eliminating the sample preparation step, allowed us to measure about four times more samples per day (about 12–15) compared to the classical method (with Pb separation using ion exchange resins). We also present, for the first time, a new method for the non-destructive sampling of manuscripts for isotopic analysis, involving the extraction of lead from the object into indicator papers soaked in 4,7-diphenyl-1,10-phenanthroline.

Related Literature

Characterizing the hygroscopicity and volatility of single levitated aerosol droplets via optical tweezers-Raman spectroscopy

Yu-Kai Tong, Teng Fang, Zhijun Wu, Min Hu, Anpei Ye

2022-09-08 Paper

DOI: 10.1039/D2VA00175F

Byproduct formation in heterogeneous catalytic ozonation processes

Tingting Wu

2023-02-14 Tutorial Review

DOI: 10.1039/D2VA00216G

Integrated chemical and biochemical technology to produce biogas with a reduced ammonia content from municipal biowaste. Validating lab-scale research in a real operational environment

Enzo Montoneri, Michalis Koutinas, Elio Padoan, Viviana Negro, Carlo Licignano, Stefano Leone, Panagiota Photiou, Michalis Kallis, Ioannis Vyrides, Freddy Liendo, Michéle Negre, Simone Solaro, Massimiliano Antonini, Davide Mainero, Anestis Vlysidis, Viktoras Konstantinidis, Dimitrios Ladakis, Sofia Maina, Apostolis Koutinas

2022-09-06 Paper

DOI: 10.1039/D2VA00068G

A flexible copper sulfide composite membrane with tunable plasmonic resonance absorption for near-infrared light-driven seawater desalination

Lu An, Chengbin Wang, Qunfeng Feng, Qiwei Tian, Wei Chai, Shiping Yang, Zhenfeng Bian

2022-01-29 Paper

DOI: 10.1039/D1VA00043H

Greenhouse gas and air pollutant emissions from power barges (powerships)

Eloise A. Marais, Orianna Akker, Christine Wiedinmyer

2022-03-21 Paper

DOI: 10.1039/D1VA00049G

Monitoring of phosphorus discharge in a sewage treatment plant with a phosphate automated analyzer

Adrian Cabo, Susana Gouveia, Claudio Cameselle, Keun-Heon Lee

2022-08-01 Paper

DOI: 10.1039/D2VA00062H

Non-stoichiometric CuxIn1−xS quantum dots for robust photodegradation of gemifloxacin: influencing parameters, intermediates, and insights into the mechanism

Deeptimayee Prusty, Sriram Mansingh, Kundan Kumar Das, Jyotirmayee Sahu, K. M. Parida

2022-09-21 Paper

DOI: 10.1039/D2VA00143H

Sodium silicate and hexametaphosphate promote the release of (oxyhydr)oxide nanoparticles from corroding iron

Benjamin F. Trueman, Javier Locsin, Evelyne Doré, Kalli Hood, Graham A. Gagnon

2022-09-26 Paper

DOI: 10.1039/D2VA00199C

You might also like

Compound Q&A

What is Ethyl 3-cyclohexylpropanoate (CAS: 10094-36-7)?

Ethyl 3-cyclohexylpropanoate is a clear, colorless to light yellow liquid with a...

10094-36-7Ethyl 3-cyclohexylpr...
Compound Q&A

How should waste containing 2-(Hydroxymethyl)-5-(methoxycarbonyl)-6-methyl-4-(2-nitrophenyl)nicotinic acid (CAS: 34783-31-8) be handled?

Waste containing 2-(Hydroxymethyl)-5-(methoxycarbonyl)-6-methyl-4-(2-nitrophenyl...

34783-31-82-(Hydroxymethyl)-5-...
Compound Q&A

How should waste containing 2,4,6-Tris(pentafluoroethyl)-1,3,5-triazine (CAS: 858-46-8) be handled?

Waste containing 2,4,6-Tris(pentafluoroethyl)-1,3,5-triazine (CAS: 858-46-8) sho...

858-46-82,4,6-Tris(pentafluo...
Compound Q&A

What precautions should be taken when handling Chloroac-nle-oh (CAS: 56787-36-1)?

When handling Chloroac-nle-oh (CAS: 56787-36-1), it is essential to wear appropr...

56787-36-1Chloroac-nle-oh
Compound Q&A

What industries use Ethyl 6-phenylimidazo[2,1-b][1,3]thiazole-3-carboxylate (CAS: 752244-05-6)?

Ethyl 6-phenylimidazo[2,1-b][1,3]thiazole-3-carboxylate is primarily used in the...

752244-05-6Ethyl 6-phenylimidaz...
Compound Q&A

Are there alternatives to alpha-(2-Bromophenyl)benzylamine (CAS: 55095-15-3) in synthesis?

Alternatives to alpha-(2-Bromophenyl)benzylamine (CAS: 55095-15-3) in synthesis ...

55095-15-3alpha-(2-Bromophenyl...
Compound Q&A

How should waste containing 2-Chloro-5-methoxypyridine (CAS: 139585-48-1) be handled?

Waste containing 2-Chloro-5-methoxypyridine (CAS: 139585-48-1) should be managed...

139585-48-12-Chloro-5-methoxypy...
Compound Q&A

What industries use 1-(4-Methoxyphenyl)-2,5-dimethyl-1H-pyrrole (CAS: 5044-27-9)?

1-(4-Methoxyphenyl)-2,5-dimethyl-1H-pyrrole (CAS: 5044-27-9) is used in various ...

5044-27-91-(4-Methoxyphenyl)-...
Compound Q&A

Are there alternatives to 3-Bromo-5-(N-Boc)aminomethylisoxazole (CAS: 903131-45-3) in synthesis?

There are alternative reagents and compounds that can be used in the synthesis o...

903131-45-33-Bromo-5-(N-Boc)ami...
Compound Q&A

What is Tungsten(IV) oxide (CAS: 12036-22-5)?

Tungsten(IV) oxide, also known as tungsten dioxide, is a chemical compound with ...

12036-22-5Tungsten(IV) oxide

Source Journal

Journal of Analytical Atomic Spectrometry

Journal of Analytical Atomic Spectrometry
CiteScore: 6.2
Self-citation Rate: 25.8%
Articles per Year: 254

The Journal of Analytical Atomic Spectrometry (JAAS) is the central journal for publishing innovative research on fundamentals, instrumentation, and methods in the determination, speciation and isotopic analysis of (trace) elements within all fields of application. This includes, but is not restricted to, the most recent progress, developments and achievements in all forms of atomic and elemental detection, isotope ratio determination, molecular analysis, plasma-based analysis and X-ray techniques. The journal welcomes full papers, communications, technical notes, critical and tutorial review articles, editorials, and comments, in addition to the Atomic Spectrometry Updates (ASU) literature reviews that are prepared by an expert panel. Submissions are welcome in the following areas, but note this list reflects the current scope and authors are strongly encouraged to contact the Editorial team if they believe that their work offers potentially new and emerging research relevant to the journal remit: Fundamental studies in the following. New and existing sources for atomic emission, absorption, fluorescence and mass spectrometry and those that provide both atomic and molecular information Sample introduction techniques for solids, liquids, gases Improvements in sensitivity, selectivity, precision, accuracy and/or robustness Isotope ratio measurements, including techniques for improving precision and mass bias correction Single channel and multichannel simultaneous detection systems Chemometrics, statistics, calibration techniques and internal standardisation Theoretical and numerical modelling of fundamental processes related to all of the above methodologies Novel or improved methodologies in areas of application including, but not limited to the following. Biosciences, including elemental, speciation and isotopic analysis in biological systems, immunoassays based on metal-labeled antibodies, bio-imaging, and nanoparticle toxicology Geochemistry Environmental science Materials science, including engineered nanoparticles and quantum dots Metrology, including reference materials Forensic analysis Food and agricultural sciences Energy Archaeometry Molecular analysis. Molecular sources for elemental and isotopic analysis Atomic sources for molecular analysis Atomic and molecular techniques simultaneously used for complementary chemical information All contributions are judged on originality and quality of scientific content, and appropriateness of length to content of new science.

Recommended Compounds

Recommended Suppliers

Disclaimer
This page provides academic journal information for reference and research purposes only. We are not affiliated with any journal publishers and do not handle publication submissions. For publication-related inquiries, please contact the respective journal publishers directly.
If you notice any inaccuracies in the information displayed, please contact us at support@chemtradehub.com. We will promptly review and address your concerns.