A robust method to improve the regression accuracy of LIBS data: determination of heavy metal Cu in Tegillarca granosa

Literature Information

Publication Date 2023-11-14
DOI 10.1039/D3AY01411H
Impact Factor 2.896
Authors

Jie Huang, Xiaojing Chen, Zhonghao Xie, Shujat Ali, Xi Chen, Leiming Yuan, Chengxi Jiang, Guangzao Huang, Wen Shi


View Original

Abstract

Tegillarca granosa (T. granosa) is susceptible to contamination by heavy metals, which poses potential health risks for consumers. Laser-induced breakdown spectroscopy (LIBS) combined with the classical partial least squares (PLS) model has shown promise in determining heavy metal concentrations in T. granosa. However, the presence of outliers during calibration can compromise the model's integrity and diminish its predictive capabilities. To address this issue, we propose using a robust method for partial least squares, RSIMPLS, to improve the accuracy of Cu prediction in T. granosa. The RSIMPLS algorithm was employed to analyze and process the high-dimensional LIBS data and utilized diagnostic plots to identify various types of outliers. By selectively eliminating certain outliers, a robust calibration method was achieved. The results showed that LIBS spectroscopy has the potential to predict Cu in T. granosa, with a coefficient of determination (Rp2) of 0.79 and a root mean square error of prediction (RMSEP) of 11.28. RSIMPLS significantly improved the prediction accuracy of Cu concentrations with a 43% decrease in RMSEP compared to the PLS. These findings validated the effectiveness of combining LIBS data with the RSIMPLS algorithm for the prediction of Cu concentrations in T. granosa.

Related Literature

Inside front cover

Cover

DOI: 10.1039/C9CP90110H

Antiferromagnetic ordering based on intermolecular London dispersion interactions in amphiphilic TEMPO ammonium salts

Jessica Exner, Steffen Eusterwiemann, Oliver Janka, Oliver Niehaus, Constantin G. Daniliuc, Rainer Pöttgen, Armido Studer

2018-11-09 Communication

DOI: 10.1039/C8CP05837G

A synergetic stabilization and strengthening strategy for two-dimensional ordered hybrid transition metal carbides

Dominik Legut, Timothy C. Germann, Shiyu Du, Joseph S. Francisco

2018-11-16 Paper

DOI: 10.1039/C8CP06458J

Silicene-supported TiO2 nanostructures: a theoretical study of electronic and optical properties

Yesukhei Jagvaral, Qing Guo, Haiying He, Ravindra Pandey

2019-04-04 Paper

DOI: 10.1039/C9CP00894B

Distribution of water in the pores of periodic mesoporous organosilicates – a proton solid state MAS NMR study

V. S. Veena, Kavya Illath, Anish Lazar, C. P. Vinod, T. G. Ajithkumar, S. Jayanthi

2018-11-01 Paper

DOI: 10.1039/C8CP04902E

Quantum-classical dynamics of the capture of neon atoms by superfluid helium nanodroplets

Miquel Blancafort-Jorquera, Arnau Vilà, Miguel González

2018-11-06 Paper

DOI: 10.1039/C8CP05140B

Energy loss analysis in photoelectrochemical water splitting: a case study of hematite photoanodes

Zhiliang Wang, Miaoqiang Lyu, Peng Chen, Songcan Wang, Lianzhou Wang

2018-08-16 Paper

DOI: 10.1039/C8CP04021D

Electrochemical tuning of capacitive response of graphene oxide

Sanjin J. Gutić, Dževad K. Kozlica, Fehim Korać, Danica Bajuk-Bogdanović, Miodrag Mitrić, Vladimir M. Mirsky, Igor A. Pašti

2018-08-07 Paper

DOI: 10.1039/C8CP03631D

Microscopic origin of the scattering pre-peak in aqueous propylamine mixtures: X-ray and neutron experiments versus simulations

Alexander I. Kuklin, Martina Požar, Anthony Baptista, Aurélien Perera

2019-04-04 Paper

DOI: 10.1039/C9CP01137D

You might also like

Compound Q&A

What are the main uses of 4-Nitrophenyl phosphate disodium salt hexahydrate (CAS: 333338-18-4)?

4-Nitrophenyl phosphate disodium salt hexahydrate is primarily used as a substra...

333338-18-44-Nitrophenyl phosph...
Compound Q&A

What are the main uses of 2-(Trifluoromethyl)-1,3-oxazole-4-carboxylic Acid (CAS: 1060816-01-4)?

2-(Trifluoromethyl)-1,3-oxazole-4-carboxylic Acid (CAS: 1060816-01-4) is widely ...

1060816-01-42-(Trifluoromethyl)-...
Compound Q&A

How should 2-Fluoro-4-biphenylcarboxylic acid (CAS: 137045-30-8) be stored?

2-Fluoro-4-biphenylcarboxylic acid should be stored in a cool, dry place at room...

137045-30-82-Fluoro-4-biphenylc...
Compound Q&A

What industries use Prednisolone-21-Carboxylic Acid (CAS: 61549-70-0)?

Prednisolone-21-Carboxylic Acid is primarily used in the pharmaceutical industry...

61549-70-0Prednisolone-21-Carb...
Compound Q&A

How should 4-(Hydrazinomethyl)-1,2,3-benzenetriol (CAS: 3614-72-0) be stored?

4-(Hydrazinomethyl)-1,2,3-benzenetriol (CAS: 3614-72-0) should be stored in a co...

3614-72-04-(Hydrazinomethyl)-...
Compound Q&A

What industries use 4-Amino-1-methyl-1H-pyrazole-5-carboxylic acid hydrochloride (CAS: 92534-70-8)?

4-Amino-1-methyl-1H-pyrazole-5-carboxylic acid hydrochloride (CAS: 92534-70-8) i...

92534-70-84-Amino-1-methyl-1H-...
Compound Q&A

What regulatory guidelines apply to dehydropachymic acid (CAS: 77012-31-8)?

Dehydropachymic acid (CAS: 77012-31-8) is regulated by various agencies. It fall...

77012-31-8Dehydropachymic acid
Compound Q&A

What is the market or research trend for 6-[(2,2-Dimethylpropanoyl)amino]nicotinic acid (CAS: 898561-66-5)?

The market and research trends for 6-[(2,2-Dimethylpropanoyl)amino]nicotinic aci...

898561-66-56-[(2,2-Dimethylprop...
Compound Q&A

How should 1,10-Phenanthroline-2,9-dicarbaldehyde (CAS: 57709-62-3) be stored?

1,10-Phenanthroline-2,9-dicarbaldehyde should be stored in a cool, dry place awa...

57709-62-31,10-Phenanthroline-...
Compound Q&A

How is 5-Carbamoyl-11-oxo-10,11-dihydro-5H-dibenzo[b,f]azepin-10-yl acetate (CAS: 113952-21-9) typically synthesized?

5-Carbamoyl-11-oxo-10,11-dihydro-5H-dibenzo[b,f]azepin-10-yl acetate can be synt...

113952-21-95-Carbamoyl-11-oxo-1...

Source Journal

Analytical Methods

Analytical Methods
CiteScore: 5.1
Self-citation Rate: 3.7%
Articles per Year: 655

Analytical Methods welcomes early applications of new analytical and bioanalytical methods and technology demonstrating the potential for societal impact. We require that methods and technology reported in the journal are sufficiently innovative, robust, accurate, and compared to other available methods for the intended application. Developments with interdisciplinary approaches are particularly welcome. Systems should be proven with suitably complex and analytically challenging samples. We encourage developments within, but not limited to, the following technologies and applications: global health, point-of-care and molecular diagnostics biosensors and bioengineering drug development and pharmaceutical analysis applied microfluidics and nanotechnology omics studies, such as proteomics, metabolomics or glycomics environmental, agricultural and food science neuroscience biochemical and clinical analysis forensic analysis industrial process and method development

Recommended Compounds

Recommended Suppliers

Disclaimer
This page provides academic journal information for reference and research purposes only. We are not affiliated with any journal publishers and do not handle publication submissions. For publication-related inquiries, please contact the respective journal publishers directly.
If you notice any inaccuracies in the information displayed, please contact us at support@chemtradehub.com. We will promptly review and address your concerns.